Experimental study of geometric and hydraulics parameters effect on local scour around inclined bridge piers group

Document Type : Original Article

Authors

Abstract
Advancement of technology in construction of structure caused to design modern type of bridge piers including inclined bridge piers group. Due to importance of identifying effective mechanisms of scour around this type of bridge piers, in this research the effect of flow parameter and level of bridge foundation on the scour depth was investigated. Bridge piers group included two inclined rectangular piers of 2.5cm width and 3.5cm length which installed at the angle of 28 degree on the top of rectangular foundation of 10cm width and 16cm length. Experiments were performed for various relative velocities, depth of flow and relative top level of the foundation from the channel bed (Z/D*) -1 up to 1. The results showed that the velocity of flow has more effect on the local scour depth in comparison of the flow depth. Comparison of results for different levels of the foundation showed that level of the foundation has significant effect on the scour depth. A maximum and a minimum scour occurred for relative foundation level 1 and -0.5. Furthermore, except of relative foundation -0.5, the scour at the inclined bridge level is more than individual pier.

Keywords


Volume 7, Issue 2 - Serial Number 13
October 2013
Pages 139-148

  • Receive Date 12 January 2012
  • Revise Date 17 December 2012
  • Accept Date 13 February 2013