Laboratory Investigations on Hydraulic Jump Characteristics Using Submerged Vanes with a Certain Angle of Attack.
Volume 17, Issue 4, Winter 2024
https://doi.org/10.22034/iwrj.2023.14471.2544
Hamidreza Bagheri, Manouchehr Heidarpour
Abstract Introduction
Hydraulic jump is a rapid energy dissipation phenomenon that falls under the sub-branch of hydraulic science. It involves a transformation of water flow from a shallow and high-velocity state to a deep and low-velocity state, leading to substantial energy dissipation. This energy dissipation primarily occurs through the conversion of kinetic energy into thermal energy, resulting in a significant reduction in destructive effects (Chanson, 2011). To control hydraulic jumps, energy dissipaters, such as baffles are used in the stilling basins. One possible alternative to the use of baffles is the implementation of artificial roughness on the channel bed. This approach involves introducing roughness elements that disrupt the water flow, which leads to unequal momentum at the inlet and outlet. Specifically, the resistance forces exerted by the roughness elements reduce the momentum at the outlet (Beirami & Chamani, 2010). Ead and Rajaratnam (2002) studied the effect of wavy beds on hydraulic jump characteristics. Similarly, Abbaspour et al. (2009) found that the use of sinusoidal-shaped roughness elements resulted in a decrease in the length and depth of hydraulic jumps. Soltani (2013) investigated the impact of submerged vanes with different heights and placements in the channel bed. The findings indicated that increasing the height of the vanes resulted in a decrease of up to 9% in secondary depths and up to 18.6% in the length of the hydraulic jump. In another study by Parsamehr et al. (2020), the influence of bed slope and inverse bed slope was examined. Additionally, Pourabdollah et al. (2020) examined the effect of inverse bed slope and positive end sill on hydraulic jump characteristics. Both laboratory studies demonstrated a reduction in length and secondary depth, with the inverse bed slope having a greater impact on reducing hydraulic jump characteristics.
Method
The experiments were conducted at the Hydraulic Laboratory of Isfahan University of Technology in Isfahan, Iran. A Plexiglas flume measuring 8 meters in length, 0.4 meters in width, and 0.6 meters in depth was used. Submerged vanes with a fixed attack angle of 30° and varying arrangements (d=0.2, 0.3 meters) were employed as roughness elements on the channel bed. The flow rate and initial Froude number were controlled by adjusting the upper and lower initial gates. Furthermore, the position of the hydraulic jump could be regulated along the channel using the lower outlet gate. The channel consisted of two reservoirs: one located at the end of the channel and beneath it, and the other situated at the beginning of the channel and in front of it. Water was pumped from a reservoir below the channel to the upstream reservoir and then directed into the channel.
To start the experiment, the pump was turned on, and both the initial and outlet gates were kept closed until the water level rose above the first gate. Then, the desired initial Froude number for the experiment was achieved by adjusting the opening of the initial gate to create the hydraulic jump. The jump could be controlled and fixed at the desired location using the outlet gate. The depths of the initial and secondary hydraulic jumps were measured using a depth gauge, while the flow rate was measured using an electromagnetic flow meter. The research involved 27 experiments with flow rates of 30, 40, and 50 l/s. Parameters such as flow rate (Q), upstream water depth (H), initial depth of hydraulic jump (D1), secondary depth of the jump (D2), and length of hydraulic jump (Lj) were measured.
Results
The research and experiments were divided into three stages. Initially, we examined variations in the depths of hydraulic jump in the presence of submerged vanes. These vanes had an attack angle of 30 degrees and were arranged at two different distances: 0.2 and 0.3 meters between each vanes groupes. The results showed that the presence of submerged vanes caused a reduction in the secondary depth of the hydraulic jump. This reduction was due to the obstruction of flow and the trapping of air bubbles in the protrusions created by the vanes. As a result, there was a decrease in energy dissipation, leading to a decrease in the secondary depth of the jump. To compare the relative length of the hydraulic jump, it was non-dimensionalized with respect to the initial depth. Then corresponding points for each experiment were plotted against the initial Froude number. The presence of submerged vanes in the channel bed was found to cause a decrease in the relative length of the hydraulic jump. On average, the relative length of the hydraulic jump decreased by 15.5% and 14.4% for experiments with attack angles of 30 degrees and vane distances of 0.2 and 0.3 meters, respectively. The reduction in the hydraulic jump was also greater compared to the classical condition. Additionally, the corresponding equations for each section were derived and presented.
Investigation of hydraulic flow properties in different vertical drop using numerical modeling
Volume 10, Issue 4, Winter 2017, Pages 33-43
Ramin Mansouri, Ali Ziaei
Abstract Drops are hydraulic structures that are commonly used in irrigation and waste water collection networks. A vertical drop balances the elevational variation between the channel slope and ground slope. Thus the flow structure is comprised of a falling jet (free overfall), a sliding or skimming jet and a circulating or mixing zone. This pattern causes the significant portion of flow energy to be dissipated through jet impact and turbulent mixing. In this study the complex flow pattern in the vertical drop with different forms of downstream channel was studied numerically. The two dimensional RANS equations accompanied with volume of fluid (VOF) method are applied. The results of the simulation are then compared to the experimental results. The details of energy loss and velocity profiles in different locations are also scrutinized.
In this study three different data sets were used. The first data set presented (case A) was measured by Lin et al. (2007). Their experiments were conducted in a flume of 8.85 m length with a glass-walled and glass-bottomed test section of 3.05 m length, 0.50 m width and 0.54 m depth. Two vertical drops with heights of 11.0 and 20.0 cm were chosen. Another set of data (case B) were collected by Chamani et al. (2005) in a ventilated vertical drop with subcritical flow at the upstream channel and sloping aprons at the downstream channel. Flow characteristics such as pool depth, downstream depth, and energy loss were measured in an 11 m length, 0.401 m width ?ume. The drop height was 0.21 m and inverse slope was set at 5 degrees. The last data set (case C) was measured by Lin et al. (2009) in a vertical drop with an end sill. The flume size was the same as in case A. Three vertical drop pools were used in this study with drop height H of 14.0 cm, pool length (L) of 16.0 cm, and end sill heights (h) of 0, 1.7 and 6.0 cm, such that the end sill ratios (h/H) were 0, 0.12, and 0.43 respectively. For the case A, four different grids (7908, 18901, 32729 and 57512 nodes) with identical flow properties were used. Instead of setting the depth and velocity, at the upstream end of the channel, a tank was set up so that the contracted flow depth and the average velocity (after the gate) match the selected critical depth and velocity. Pressure outlet boundary conditions (BC) were set at top of the channel, the channel outlet and at the air vent. The flow depth results were converging and a good agreement with experimental data was observed with the two smallest grids. However, to access better resolution, the 57512-node grid was preferred and grids with almost the same cell size were adopted for other numerical simulations. The laminar model did not produce satisfactory flow depth and velocity along the drop structure. The results of the most commonly used two-equation turbulence models (k-? and k-?) were identical. Furthermore, the standard wall function produced better results compared to non-equilibrium wall function. Thus the standard k-? with the standard wall function was preferred for other simulations.
Grid study showed that numerical results of a 57512-node grid had the best agreement with the experimental values. The desired downstream channel length was preferred to be 1.5 meter, and the standard k-? turbulence model produced the best results in a horizontal apron drop. The numerical free-surface profiles followed the theoretical equations very well. Due to higher circulation ratio and occurring a hydraulic jump in the pool, the greatest energy dissipation was obtained in the drop with an end sill. The drop with adverse apron was in the second position and the minimum dissipation occurred in the horizontal apron drop. The numerically calculated velocity profiles mimicked the experimental results all over the falling, sliding or skimming jet regions. The numerical model was not so successful in the mixing region behind the nappe which is possibly due to weakness of the turbulence models. Using enhanced turbulence model will decrease discrepancies in this region. It can be concluded that the 2D numerical model is able to produce satisfactory results in order to design and evaluate a vertical drop, which in turn can aviate the need to endeavor too much effort and financial cost to construct a suitable experimental model in the laboratory.