Quantitative and Operational Performance Comparison of Multi-Objective Evolutionary Algorithms NSGA-II, MOEA/D, and AGE-MOEA in Water Distribution Network Pressure Management Optimization
Articles in Press, Accepted Manuscript, Available Online from 26 July 2026
https://doi.org/10.22034/iwrj.2026.15067.2646
Farzin Sayad beyranvand, Masoud Shakarami
Abstract Introduction:
Water distribution networks in arid regions face persistent challenges including pressure standard maintenance, infrastructure cost reduction, and water loss management. Iran, with annual precipitation of 240–250 mm, confronts severe water scarcity, making efficient network management critically important. Leakage — an unavoidable phenomenon in distribution systems — is directly governed by network pressure, rendering pressure management a primary strategy for loss reduction (Lambert, 2001). Recent advances in multi-objective evolutionary algorithms have expanded optimization capabilities for water distribution networks. While NSGA-II and MOEA/D have been extensively applied in hydraulic engineering, AGE-MOEA — developed by Panichella (2022) based on non-Euclidean Pareto front geometry approximation — has not previously been evaluated in water distribution optimization contexts, as confirmed through systematic searches of Scopus and Web of Science databases. Furthermore, existing studies predominantly assess Pareto front quality metrics while neglecting the operational implementability of optimization outputs, particularly the stability of pressure-reducing valve (PRV) hourly scheduling patterns under real operating conditions. This study presents a comprehensive two-phase framework integrating hydraulic simulation (WaterGEMS/EPANET) and evolutionary optimization (Python/DEAP/WNTR) to evaluate NSGA-II, MOEA/D, and AGE-MOEA across benchmark networks (Hanoi, Balerma) and the real Poldokhtar western zone network, assessing both Pareto front quality and practical operational feasibility
Materials and Methods:
This study developed an integrated framework combining hydraulic simulation and multi-objective evolutionary optimization across three water distribution networks of increasing complexity: the Hanoi benchmark (34 pipes, 32 nodes, single gravity reservoir), the Balerma irrigation network (454 pipes, 443 nodes, four reservoirs), and the real Poldokhtar western zone network (261 pipes, 206 consumption nodes, one 5,000 m³ gravity reservoir, two pressure-reducing valves). Hydraulic models were initially constructed in WaterGEMS and converted to EPANET 2.2 standard format, with pressure-driven analysis (PDA) implemented through the WNTR library in Python, where nodal demand follows q_i^actual=q_i^demand⋅((P_i-P_i^min)/(P_i^req-P_i^min ))^0.5for P_i^min≤P_i≤P_i^req. The Poldokhtar model was calibrated against field measurements of reservoir outflow and PRV discharge rates, achieving acceptable agreement between simulated and observed values; full nodal pressure calibration was constrained by limited field sensor deployment. Three multi-objective evolutionary algorithms — NSGA-II (dominance-based), MOEA/D (decomposition-based), and AGE-MOEA (geometry approximation-based) — were implemented using the DEAP library with identical computational budgets of 200,000 function evaluations (population N=200, generations=1,000), SBX crossover (pc=0.9, ηc=20), polynomial mutation (pm=1/n, ηm=20), and 30 independent runs with random seeds 1–30. For Hanoi and Balerma, decision variables comprised all pipe diameters selected from discrete commercial sizes, with objectives of minimizing total network cost (Z₁) and pressure deviation from permissible ranges. For Poldokhtar, 53 decision variables encompassed hourly scheduling coefficients of two PRVs (48 variables) and diameters of five selected pipes (5 variables), with three objectives: minimizing total hydraulic penalty from pressure and velocity violations (Z₁), minimizing excess pressure (Z₂), and minimizing the sum of selected pipe diameters (Z₃). Algorithm performance was evaluated using Hypervolume (HV) with reference point r=1.1×fmax and Inverted Generational Distance (IGD) computed against a reference front constructed from all non-dominated solutions across 30 runs of all three algorithms, where higher HV and lower IGD indicate superior performance.
Results and Discussions:
Performance evaluation across three networks revealed distinct algorithmic behaviors reflecting fundamental differences in search mechanisms. On the Hanoi network, NSGA-II achieved the only fully feasible solution with zero pressure deviation at a network cost of $77,551, demonstrating superior capability in navigating tight hydraulic constraints, while AGE-MOEA recorded the highest overall Pareto front quality metrics (HV=4.7, IGD=1.87) and MOEA/D performed weakest (HV=3.6, IGD=3.75) due to its inherent sensitivity to objective scale differences — the Tchebycheff scalarization function becomes dominated by the larger-magnitude cost objective, disrupting convergence toward feasible pressure-compliant solutions. On the large-scale Balerma network (454 pipes, 10⁴⁵⁴ search space), AGE-MOEA maintained its quantitative superiority (HV=0.85, IGD=0.019), followed closely by NSGA-II (HV=0.82, IGD=0.024), while MOEA/D exhibited significant diversity loss (HV=0.61, IGD=0.041), confirming that decomposition-based approaches struggle with high-dimensional design spaces where neighborhood assumptions break down. The Poldokhtar three-objective case produced the most operationally informative results. Pareto front comparison (Z₁: total hydraulic penalty vs. Z₂: excess pressure) revealed that AGE-MOEA dominated NSGA-II across the majority of the objective space in the Z₁ range of 5,750–6,000, delivering lower excess pressure for equivalent hydraulic penalty values, while both algorithms provided substantially wider solution diversity than MOEA/D, which concentrated exclusively in the high-penalty low-excess-pressure region (Z₁>6,050, Z₂≈28,800–29,600) — a computationally significant weakness for multi-objective optimization. Hypervolume convergence analysis (Figure 15) revealed an important distinction: MOEA/D achieved the highest final cumulative HV (4,603,078) compared to NSGA-II (4,089,945) and AGE-MOEA (3,369,721), which does not contradict its weaker Pareto front coverage but reflects its deep convergence within a narrow objective region — a fundamentally different metric capturing exploration history rather than final solution quality. PRV hourly scheduling analysis exposed a critical operational dimension absent from purely quantitative assessments: despite their Pareto front superiority, NSGA-II and AGE-MOEA generated highly oscillatory valve settings fluctuating between 18–23 m within single-hour intervals, with quantitative indicators confirming significantly higher variance, directional change frequency, and oscillation amplitude compared to MOEA/D, which produced conservative near-constant patterns with only minor adjustments — most notably a smooth transition at hour 7 for PRV-1. This operational contrast, supported by the equal-weight MCDM compromise solution extracted from each algorithm's Pareto front, demonstrates that Pareto front quality metrics alone provide an incomplete basis for algorithm selection in real operational contexts: AGE-MOEA is recommended for large-scale design optimization where Pareto coverage is paramount, NSGA-II excels when strictly feasible solutions under tight hydraulic constraints are required, and MOEA/D — despite its quantitative limitations — produces the most operationally stable PRV scheduling patterns suitable for direct field implementation, highlighting a fundamental trade-off between mathematical optimality and engineering practicability that warrants explicit consideration in future water network optimization frameworks.
Conclusion:
This study presented a comprehensive evaluation of NSGA-II, MOEA/D, and AGE-MOEA for water distribution network optimization through an integrated WaterGEMS-EPANET-Python framework. AGE-MOEA demonstrated superior Pareto front coverage in large-scale networks, while NSGA-II proved most effective for constraint-intensive design problems requiring fully feasible solutions. Despite weaker Pareto front diversity, MOEA/D generated operationally implementable PRV scheduling patterns with minimal oscillations, revealing a fundamental trade-off between algorithmic optimality and practical deployability. Algorithm selection should therefore be governed by decision-maker priorities: AGE-MOEA for Pareto quality, NSGA-II for constraint satisfaction, and MOEA/D for operational stability. Quantified leakage reduction requires dedicated pressure-leakage modeling in future research.
Development of a Hydraulic Simulation Model and Performance Analysis of Time- and Flow-Modulated Pressure Reducing Valves for Leakage Reduction in Urban Water Distribution Networks Using WaterGEMS Software.
Articles in Press, Accepted Manuscript, Available Online from 07 October 2026
https://doi.org/10.22034/iwrj.2026.15236.2666
Seyyed Mohammad Kazem Banihashemi Emam gheysi, Ali attarzadeh, Hamide Jafari
Abstract Introduction:
Water distribution networks are vital urban infrastructure, yet a substantial share of the water they carry is lost before reaching consumers as non-revenue water, largely through real leakage from mains, distribution pipes and service connections. Leakage wastes scarce water, raises production and pumping costs, reduces reliability and shortens asset life. Hydraulic pressure is the dominant driver of leakage and pipe bursts, so pressure management is widely regarded as one of the most effective and economical ways to reduce real losses. Calibrated hydraulic models such as Water GEMS allow pressure-control strategies to be tested before field implementation. However, most published studies address large networks or specific hydraulic conditions, and small networks with pronounced elevation differences, particularly in Chaharmahal and Bakhtiari Province, remain little studied. In such networks a single fixed pressure setting can cause excess pressure in low-lying zones and deficits at high points. This study therefore develops and validates a Water GEMS model of the Pordanjan distribution network and compares three pressure-reducing-valve (PRV) strategies, namely fixed-outlet, time-modulated and flow-modulated control, in terms of pressure, leakage reduction and practical feasibility.
Materials and Methods:
Pordanjan, a town in Farsan County, Chaharmahal and Bakhtiari Province, is supplied by gravity from a single concrete ground reservoir at the highest point of the town. The network comprises about 37 km of pipes (25–160 mm; 78% polyethylene, 16% steel, 6% asbestos cement), 207 nodes, roughly 3,000 service connections and six demand zones, serving about 9,400 people (projected 13,700 by 2041). Digital maps, as-built drawings, elevation data, customer locations, demand patterns and field pressure records were obtained from the provincial water and wastewater company, drawn in AutoCAD, checked against GIS data and site surveys, and imported into Water GEMS, where geometric errors were corrected. Hydraulic analysis relied on mass and energy conservation, with the Hazen–Williams equation for head loss.
Real losses were estimated by minimum night flow (MNF) analysis. Night leakage was extended to 24 hours through the pressure–leakage relationship Q = C × P^N1, with N1 = 1.15 and C calibrated from hourly model pressures. Network performance was also expressed by the Infrastructure Leakage Index (ILI).
The model was calibrated by adjusting pipe roughness and demand patterns against pressures recorded every 15 minutes for 48 hours at eight points in zones 1,3, 4 and 6, and was then validated with independent pressure and flow data. Three scenarios were simulated over an extended 24-hour period: (1) constant PRV outlet pressure, selected by a sensitivity analysis of 30–55 m; (2) time-modulated outlet pressure following the daily demand pattern; and (3) flow-modulated outlet pressure adjusted to instantaneous flow and controlled through the critical node in zone 6. All scenarios were constrained by a minimum service pressure of 20 m. Indicators were mean, maximum, minimum and standard deviation of nodal pressure, minimum night flow, daily leakage, annual water saving, and the number of nodes above 50 m or below 20 m. The annual economic value of the saved water was examined by sensitivity analysis at 10, 20 and 30 thousand tomans per cubic meter.
Results and Discussions:
The calibrated model reproduced field behavior well: pressure RMSE was below 5%, and differences between simulated and measured pressure and flow were under 10%. The baseline simulation showed strongly non-uniform pressure, from 15.2 to 67.3 m (mean 41.2 m, standard deviation 11.9 m), with 116 nodes above 50 m and 38 below 20 m. Real losses were about 850 m³/day, roughly 22% of inflow and above the national average of 20–25%. MNF was 10.44 L/s, of which 66.5% (6.94 L/s) was real leakage, and the ILI was 3.8. Losses stem mainly from ageing pipes, corrosion-related cracks and weak joints aggravated by excess pressure, and daily pressure fluctuations impose continual mechanical fatigue on pipes and fittings.
All three scenarios improved on the baseline. A constant outlet pressure of 45 m proved optimal: lower values starved the upper zones, higher values limited leakage reduction. It cut mean pressure from 41.2 to 35.8 m, nodes above 50 m from 116 to 32, and daily leakage from 850 to 715 m³ (15.9%), saving 49,275 m³/year. Its weakness is that pressure stays at 45 m through low-demand night hours, when 30–35 m would suffice, and the setting must be revised as the population grows.
Time-modulated control lowered mean pressure to 33.6 m, night flow to 7.98 L/s and daily leakage to 655 m³ (22.9%), saving 71175 m³/year, while holding about 22 m in zone 6 at peak demand. Its limitations are the need for a programmable valve (20–50% costlier than a simple PRV), periodic re-tuning of the time pattern, and no response to sudden demand changes such as fires or pipe bursts. Flow-modulated control, with set points of about 35–38 m at low flow and 48–50 m at peak flow, gave the best technical performance: mean pressure of 32.1 m, pressure standard deviation of 7.8 m, only 8 nodes above 50 m, and daily leakage of 605 m³ (28.8%), saving 89425 m³/year. However, it requires intelligent controllers, flow sensors and the highest investment.
Pressure reduction did not compromise service, as no node fell below 20 m in any scenario. The sensitivity analysis gave annual benefits of about 0.49–1.48, 0.71–2.14 and 0.89–2.68 billion tomans for the three scenarios, and the ranking did not change with water value. Because equipment costs were unavailable, no payback period was calculated. Considering technical performance, cost and implementation constraints, the time-modulated scenario was judged the most suitable option under present conditions. The findings agree with earlier studies showing that pressure management can cut leakage substantially without extensive pipe replacement.
Conclusion:
A calibrated Water GEMS model proved an effective tool for diagnosing pressure problems and comparing control strategies in the Pordanjan network, where topography causes excess pressure in low zones and deficits at high points. All three PRV strategies reduced excess pressure and leakage (by 15.9%, 22.9% and 28.8%) while keeping service pressure above 20 m. Time-modulated control is recommended in the short term for its balance of leakage reduction and cost, with flow-modulated control as a longer-term upgrade. Continuous monitoring of pressure and minimum night flow is needed to sustain the gains. Future work should use long-term seasonal data, SCADA-based real-time control and life-cycle cost analysis.
Keywords: Leakage, Pressure Management, Water Distribution Network, Water Loss, Water GEMS
Author Contributions:
First author: Data collection and preliminary analysis, and manuscript writing.
Second author: Data analysis, guidance, editing and revision of the manuscript, and verification of results.
Third author: Data analysis, guidance, editing and revision of the manuscript, and verification of results.
Data Availability Statement:
The data of this study are part of the M.Sc. thesis of Seyyed Mohammad Kazem Banihashemi Emam Gheysi (Civil–Environmental Engineering, Faculty of Engineering, Qom University of Technology). Part of the data was obtained from the Chaharmahal and Bakhtiari Provincial Water and Wastewater Company.
Funding:
The authors thank the Chaharmahal and Bakhtiari Provincial Water and Wastewater Company for providing data and information and for financial support of this research.
Ethical Considerations:
The authors observed ethical principles in conducting and publishing this work, including avoidance of data fabrication, falsification, plagiarism and misconduct, and all authors confirm this
Field measurement and hydraulic simulation of drinking water transmission lines and distribution network (case study: Chavar city, Ilam province)
Volume 18, Issue 4, Winter 2025, Pages 1-8
https://doi.org/10.22034/iwrj.2024.14845.2623
hosna Fatahi, Jafar Mamizadeh, amir Baqi, hamed Abdullahi
Abstract Extended Abstract
The set of factors including rainfall decrease, population increase, excessive use and waste of water in water supply networks has caused the world to face a serious shortage of water resources. Preventing water loss is one of the most important indicators of preserving water resources. In all sectors of water consumption (agriculture, drinking water, industry, etc.), water loss is an inevitable challenge. In urban water distribution networks, the high amount of water loss is due to their large size and multiple connections.
Chavar city located in Ilam province, Iran, 15 kilometers northwest of the provincial capital. The population of this city is 10,554 people, of whom 5,831 live in the central part of Chavar city. Most of the city's distribution network pipes are made of asbestos, polyethylene pipes and even some metal pipes with small diameters. There are asbestos pipes with diameters of 50, 110, 100 and 200 mm, polyethylene pipes with diameters of 110 and 125 mm; and steel pipes with diameters of 25, 38 and 200 mm. With field surveys, the simulated water network was updated and the hydraulic analysis of the network was done by Auto CAD, GIS, Water GEMS software. According to the location of the subscribers, their consumption was allocated to the nearest pipe. In order to measure the pressure in different points of the network, oil type (glycerin) gauges were used. An ultrasonic portable flow meter was used to measure the flow rate.
In the first step of analysis of the transmission line, the flow rate was measured at the water supply well, the transmission pipeline and the two reservoirs in the transmission system. The design of the transmission line in two sections was modeled by Water GEMS software. The first part included a well to a concrete reservoir of 700 cubic meters, and the second part included a reservoir of 700 to a 1000 cubic meters. There were four pumps in this network. The PMP-1 pump belonged to the well, which had a flow rate of 56.29 liters per second and a pump head of 153.3 meters. PMP-2, PMP-3 and PMP-4 pumps were connected to the 700 cubic meter tank, which operated as two active pumps and one in standby mode during the day, and one active pump with two pumps in standby mode during the night. In the case of two active pumps, each pump had a flow rate of 38.44 liters per second and a head of 158.3 meters. The pipelines analyzed in the software showed that the first transmission line transferred a flow rate of 56.2 liters per second at a velocity of 1.79 meters per second to the 700 cubic meter reservoir. The second transmission line transferred the flow rate of 76.8 liters per second at a velocity of 1.22 meters per second for the 1000 cubic meter reservoir to the distribution network. The velocity in both pipelines was acceptable according to the range of design criteria, and the flow rate was completely consistent with the design flow rate of the pumps. The results of network simulation showed that 57% of the network nodes were in the peak consumption mode. This was due to the level difference of more than 130 meters between the reservoir and the consumer, the absence of pressure reducing valves. , the pressure was outside the permissible range of 14 to 45 meters of water. Also, 73 percent of the pipelines lack the optimal velocity of 0.3 to 2.5 meters per second due to the inappropriate diameter of the pipelines. In the second simulation mode with 0.7 maximum flow rate (corresponding to the lowest amount of consumption in the coldest seasons of the year), the pressure in the nodes was improving, and 64.5% of the nodes had the optimal pressure, but the routside the standard permissible range in 84% of the pipelines. The simulation in the transmission lines was validated by comparing the discharge field measurement using the ultrasonic flow meter and the value calculated in the software. The pressure of the network was measured at several points by the pressure gauge. Then these values were compared with the pressures obtained from the simulation in the lowest consumption mode. The results indicated that there was a good correlation between the hydraulic simulation results and the field evaluation of the network.