Author = منوچهر حیدرپور
Marine structures

Examining the effectiveness of the model in the simulation of hydraulic jump under initial negative step, reverse slope and bed roughness

Volume 18, Issue 2, Spring 2024, Pages 1-13

https://doi.org/10.22034/IWRJ.2024.14757.2598

Farzin Sayad beyranvand, Manouchehr Heidarpour, Nahid Pourabdollahi

Abstract Hydraulic jump is a type of rapid variable currents, which has surface turbulence and twisting of water from the beginning to the end, and is known as an energy-wasting phenomenon. In this research, the numerical simulation of hydraulic jump was done in the case of initial negative step of 3 and 6 cm, bed roughness of 2 cm and reverse slope of 1.5 and 3%. RNG and k-ε disturbance models were used in this research. Also, two types of uniform and non-uniform grids were used. According to the numerical modeling results, the RNG turbulence model calculated the turbulence of the flow field more accurately compared to the K-ε turbulence model. The statistical indices of NRMSE, R2 and d for the numerical simulation results of the water surface profile were obtained as 10.1, 0.993 and 0.994 respectively. Also, the values of these indices were calculated for the speed profile simulation results, respectively 16.36, 0.944 and 0.97. The error of the numerical model in calculating the values of the velocity profile was higher compared to the water level profile, which can be attributed to the severe flow turbulence and instantaneous velocity fluctuations in any vertical direction within the range of occurrence of hydraulic jump and intensification of air-water mixing. Comparison of the simulation results with the laboratory results of water surface profile, velocity profile, conjugate depth ratio, rolling length and hydraulic jump length and energy loss ratio shows the capability of the numerical model in the three-dimensional simulation of the free hydraulic jump flow field.

Hydraulic sediment and river engineering

Investigation of bed shear force and boundary layer thickness in the abrupt expanding stilling basin with negative step

Volume 16, Issue 3, Autumn 2022

https://doi.org/10.22034/iwrj.2022.13774.2383

Amir Esmaeil Hamidinejad, Zahra ghadampour

Abstract Introduction

Hydraulic jump is a phenomenon that occurs due to the change of current from supercritical to subcritical. In water-depleting buildings, or relaxation ponds, methods are usually used to control the jump in the ponds, which can be used to stabilize, control, and reduce the length and depth of the secondary hydraulic jump. In a stilling basin, different main variables such as floor geometry (including initial and final steps, etc.), plan geometry (including gradual or sudden divergence), bed roughness (to increase shear force) and change in flow rate (by adding It is localized or extracted from water) causes a change in the dimensions of the hydraulic jump or a reduction in the destructive energy of the initial flow.

Methodology

The experiments were conducted in a flume with Plexiglas bed and walls, which was 8.0 m in length, 0.40 m in width, and 0.60 m in depth. It was connected to a hydraulic circuit allowing for recirculation of discharge. The discharge in the flume was obtained from an overhead tank. The discharge was measured by a calibrated magnetic flow meter located in the supply line with ±5% accuracy. Water entered the flume under a vertical sluice gate, 1.2 m deep. The supercritical depth was controlled by the upstream sluice gate, while the tailwater depth was controlled by the downstream sluice gate. The point gauge with an accuracy of 1 mm was used for the measurement of the depth of water at various locations in the flume. In each experiment, the flow velocity was measured by using a pitot tube in several sections of the jump length. In this study, the expansion ratio is considered in the range of 0≤B≤2, and the height of steps are 0≤B≤6. In total, 108 experiments have been conducted in the range of Froude numbers of 4.9 to 9.5 and discharge 30 to 50 (L⁄s).

Results and Discusspn

In this study, the velocity profiles were measured in the jumps on abrupt expanding channel with a negative step. The velocity profile variations are similar to that of a wall jet, so the boundary layer growth and the maximum velocity, um, decrease with increasing longitudinal distance (x) from the beginning of the jump. To investigate the similarity of these velocity profiles, the length scale (b); the value of y at which (u=0.5u_m ) and ∂u⁄(∂y<0) was determined. Results shows the dimensionless velocity profiles for all expanding data and the negative step in experiments in which velocity profiles are measured. The maximum velocities in the sudden divergent channel and the eternal negative bed step occur at higher points than in the classical wall nozzle.

In addition, the results shows the shear force coefficient ε increasing with the Froude number. The shear force coefficient for hydraulic jump in a abrupt expanding channel is 14 times that of hydraulic jump in a rectangular channel, While the negative step reduces the shear force coefficient, which has not been mentioned in any research. As can be seen from the results, the shear force coefficient, in addition to the landing number, also depends on the parameters of divergence ratio, relative step height and conjugate depth ratio.

Conclusions

In the present study, the velocity and shear force profiles in the hydraulic jump in an abrupt expanding channel with a negative step were investigated. In general, the shear stress coefficient of the bed increases with increasing Froude number. The values of shear force coefficient are presented using laboratory data as a function of landing number, divergence ratio and relative height of the step. The shear stress coefficient of the bed in an abrupt expanding channel with a negative step is 14 times that of the classical case. The velocity profiles at different stages of the hydraulic jump in an abrupt expanding channel with a negative step are similar to the classical mode. However, the maximum velocity in these experiments is higher than that of the classic wall jet, and the thickness of the boundary layer is greater when jumping in a sudden divergent channel with a negative step. The value of the dimensionless border layer (δ/b) in the present study was equal to 0.57, which is higher than the corresponding value in the classical case (0.16).

Hydraulic

Study of the effect of adverse slope and elementary negative step on hydraulic jump characteristics

Volume 15, Issue 4, Winter 2022, Pages 35-43

https://doi.org/10.22034/iwrj.2021.11163

Keikhosro Saiadi, Manouchehr Heidarpour, Zahra ghadampour

Abstract Stilling basins are a short section of the floor of channels that are constructed as special structures at the end of the spillways and any other site that creates a supercritical flow to control the hydraulic jump. The shorter their lengths, they will be the more economically viable. One of the most important topics in the study of reducing the destructive energy of the flow is hydraulic jump. Hydraulic jump control is carried out in order to reduce the damage of the downstream structures. A hydraulic jump is one of the most rapidly varied flows occurring when the flow is altered from a supercritical state to a subcritical one in a part of its path. Researchers have always tried to control the hydraulic jump to prevent severe damage to downstream hydraulic structures. The high cost of building recreational pools has encouraged researchers to reduce sequent depth, jump length and reduce energy losses. There are several methods to reduce the sequent depth and length of the hydraulic jump, as well as increasing the energy loss of the hydraulic jump, such as increasing the adverse slope of the bed or using roughness in the channel floor. In addition to reduce the dimensions of the hydraulic jump for the cost-effective construction of the stilling basin, the stabilization of the hydraulic jump at the pool site is also very important. A sudden drop in the bed (negative step) stabilizes a horizontal hydraulic jump of channel adjacent to the step for a wide range of sequent depths. This paper introduced a new solution for the hydraulic jump on adverse slope and negative step to the difference between the upstream and the downstream momentum fluxes.
The channel used in this research had a rectangular shape with a length of 8, a width of 0.4 and a height of 0.6 meters. The walls and floor of this channel were made of transparent Plexiglas sheet. This channel was fed by a pump with a maximum discharge of 50 liters per second. In order to increase the initial Froude number before the upstream sliding gate, the tank height is considered to be 1.25 m. To create the stairs at the beginning of the channel, Teflon sheets with thicknesses of 3 and 6 cm were used. Taking into account the zero height, three different heights were considered for the stairs. In this study, three angles of zero, 3 and 6 degrees were used for the adverse slopes. To change the slope of a false plate with a length of 3 meters was applied that its sloping part continued to a distance of 2 meters from the gate, the slope of which was adjustable. This plate was located at the bottom of the channel, just after the initial gate, where the jump occurs completely in this part of the channel. A sliding gate was installed at the inlet of the flume to create the jump. In addition, another valve was used at the end of the flume to stabilize the jump. In the performed experiments, the downstream gate was adjusted so that the start of the jump occurred at the point of change in the height of the channel. In the current study, the total number of the experiments was 81 that performed in the range of 4.5 to 9.5 Froude numbers.
In this research, the combined effect of using three inverse slopes and three elementary negative step elevations on hydraulic jump characteristics (including: sequent depths, jump length and energy loss) were studied in Froude numbers of 4.5 to 9.5. The results showed that by increasing the adverse slope of channel reduced the sequent depths, jump length and energy loss by 12.6%, 13.9% and 16.8%, respectively. By increasing the negative step, the ratio of sequent depths and jump length increased by 5.66% and 6.2%, respectively; while, energy loss decreased by 2.6%. The combination of the adverse slope and negative step reduced the sequent depths, jump length and energy loss by 12.42%, 14.8% and 3%, respectively, and also created a shear of 12.56 times equal to the conditions of a smooth bed. Therefore, the negative step only stabilizes the jump in the stilling basin, and the adverse slope makes this jump stabilization difficult.

Investigation of of shear force, boundary layer and cavitation phenomenon in abrupt expanding stilling basin with rough bed

Volume 15, Issue 2, Spring 2021, Pages 1-9

bashir fallahi, Manouchehr Heidarpour

Abstract One of the most important subjects in reducing the destructive energy of the flow is hydraulic jump. Hydraulic jump control is carried out to reduce the damage to downstream structures. A hydraulic jump is one of the most rapidly varied flows occurring when the flow is altered from supercritical state to subcritical. Most researchers have been tried to provide conditions for more energy dissipation by changing the design of stilling basin. In recent years, it has been determined that divergence, the presence of roughness or the formation of slopes in the basement of the stilling basin, could be effective in reducing jump dimensions and be economically feasible. An appropriate method for controlling the hydraulic jump is to use the bed roughness. In addition to reducing the length and depth and increasing the hydraulic jump energy loss, roughness stabilizes the jump in the position of the stilling basin. Besides, when the required depth for a classic hydraulic jump cannot be provided, or the cost of excavation to lower the bed of the stilling basin is not economical, construction of an expansion in the channel is a way to ensure the formation of the hydraulic jump in the stilling basin. Ead and Rajaratnam (2002) showed that the axial velocity profiles at different sections in the hydraulic jump were similar with some differences from the profile of the simple plane wall jet. Abbaspour, et al. (2009) also indicated that the longitudinal velocity profiles at different sections are similar, but they are a little different from the profiles of classic hydraulic jumps. The results showed that the dimensionless thickness of the boundary layer ( ) for jumps on corrugated beds was about 0.57, while was 0.16 for classic jumps on a smooth bed. The shear force coefficient ) for jumps on corrugated beds is approximately 10 times that for jumps on smooth beds, and the shear force coefficient showed a sharp growth with increasing Froude number.
The experiments were conducted in a flume with Plexiglas bed and walls, which was 8.0 m in length, 0.40 m in width, and 0.60 m in depth. It was connected to a hydraulic circuit allowing for recirculation of discharge. The discharge in the flume was obtained from an overhead tank. The discharge was measured by a calibrated magnetic flow meter located in the supply line, with ±5% accuracy. Water entered the flume under a vertical sluice gate, 1.2 m deep. The supercritical depth was controlled by the upstream sluice gate, while the tailwater depth was controlled by the downstream sluice gate. The point gauge with an accuracy of 1 mm was used for the measurement of the depth of water at various locations in the flume. In each experiment, the flow velocity was measured by using a pitot tube in several sections of the jump length. Twenty-five piezometers were installed on a false floor, at the site of the hydraulic jump. Phenomenon during the jump was investigated by these piezometers. The divergence ratio was considered in the range of , and natural rough bed conditions with 0 ≤ ks/d1 ≤ 0.9. In total, 81 experiments was conducted in the range of Froud numbers of 4.9 to 9.5 and discharge of 30 to 50 . For the rough bed, the reference level was assumed coincident with the plane passing at the top of the particles that the height was assumed equal to the median size (d50).Primary and sequent depths were measured by point gauge and velocity profiles by pitot tube.
By investigating the velocity profiles, it was found that the relative thickness of the boundary layer  was 0.51, while for the classical jump was 0.16.When both roughness and abrupt expansion parameters were used, the value of shear force coefficient (at expansion ratio of 2 and roughness size of 2.2 cm) was 14.7 times the shear force factor in classical jump on average. The water fluctuations, pressure variations the probability of existence cavitation were studied using the piezometers installed at the bottom of the stilling basin. As the expansion ratio and the roughness size increased, the cavitation coefficient decreased. The measurements showed that there was no cavitation in these experiments. In the most critical case, the cavitation coefficient in the structure did not fall below 5.7.

Conjunctive use management of surfacewater and groundwater resources in drought condition. Case study : West of Qazvin plain irrigation network

Volume 15, Issue 1, Winter 2021, Pages 97-109

Ahmad Mehrabi, Manoghehr Heidarpour, Hamid Reza Safavi

Abstract Deficit irrigation was investigated for major crops in the west of Qazvin plain irrigation network in order to reduce the water consumption in the agricultural section, and provide suitable method for the conjunctive use of surface and groundwater resources in the irrigation networks. Solving the optimization problem of conjunctive management models for surface and groundwater resources using meta-heuristic algorithms can be considered as one of the efficient solutions. In this regard, comprehensive studies have proved the ability of these algorithms. The purpose of this study is to manage the conjunctive use of surface and groundwater using Gravitational Search Algorithm (GSA) with the objective of maximizing annual Net Benefit (NB) in water scarcity conditions.
The study area is the west region of the Qazvin plain’s irrigation network. The scenarios consist 30 items, combination of 6 levels of deficit monthly irrigation percentage (0, 0-10, 0-20,0- 30, 0-40 and 0-50%) and 5 levels of groundwater allocation percentage (80, 85, 90, 95, 100% of maximum extraction).
Based on SPI drought index, the water year 86-87(2007-2008) was selected as the base year of drought. In this year, the allocation of surface water was about 30.1 million m3 and the total groundwater extraction for agriculture was estimated to be about 126.7 million m3. The optimization model was prepared based on the GSA. The crop pattern in the study area was selected based on the crops in the latest pattern suggested by Jihad Keshavarzi, including fall crops of wheat, barley and rapeseed, and summer crops of sugar beet, tomato, corn- and fodder-maize. The gardens’ composition maintained and their water demands were subtracted from the total water consumption.
The decision variables in this optimization model were 82 items, which include 7 cultivation areas, 12 monthly surface water extractions, 12 monthly groundwater extractions and 51 monthly irrigation demands for different crops that were separately defined by specific limits in the program. The dimension and iteration numbers were 100 and 200,000, respectively. The amounts of water demand for the selected crops were calculated separately. The potential evapotranspiration was calculated from the data of Qazvin Synoptic Station using CROPWAT8 program with the calculation method of modified Penman-Monteith FAO.
The limits of the optimization model include a limit related to the maximum annual volume of surface water allocation, a limit related to the maximum annual volume of groundwater allocation, 12 limits related to the amount of monthly allocation of surface and groundwater resources, and a limit related to the maximum area of optimal crop areas. In order to define the yield function of the main crops, the results of Tafteh research (2014) in Qazvin plain were used. The optimization model was executed for different scenarios and the results were analyzed.
In comparison between scenarios with equal level of deficit irrigation, the percentage of fall crops increases along with decreasing the groundwater extraction, and in comparison between scenarios with equal groundwater extraction, the percentage of fall crops increases along with increasing the deficit irrigation percentage, Also, in scenarios with equal level of deficit irrigation, the percentages of wheat and tomato increase slightly along with decreasing groundwater extraction.
Increasing the percentage of wheat and rapeseed cultivation in fall crops and decreasing the percentage of tomato, corn and fodder maize cultivation are other changes in the cultivation pattern in the condition of deficit irrigation. Decreasing the volume of groundwater extraction and increasing the deficit irrigation levels cause decrease and increase in the area of cultivation, respectively.
In full irrigation treatment by selecting the optimum crop pattern, groundwater extraction reduces from 5 to 20% and groundwater resources saved up to 25.3 million m3 while NB decreases from 1.7% to 10.9%. Also by increasing the amount of deficit irrigation to 50% in scenarios with equal groundwater extraction, the NB decreases by about 6.4% to 10.7%. In comparison of the NBPD (Net Benefit Per Demand) between different scenarios, the scenarios with 20% reduction in groundwater extraction and the one with full irrigation obtained the highest value of NBPD, and the scenarios with deficit irrigation up to 40 and 50% obtained the lowest value of NBPD.
The deficit irrigation operations caused an increase in cultivated areas from 41 to 54% at deficit irrigation percentage of 50% compared to the full irrigation treatments, although it reduces the NBPD by the maximum amounts of 5.9 to 10.3%. In general, the rate of decrease in the NBPD percentage is less than the rate of decrease in the groundwater extraction percentage and the rate of increase in the deficit irrigation percentage, due to the high productivity resulted from deficit irrigation and optimal water use.
In all scenarios, most of the water demands were supplied from groundwater resources (about 77.0 to 80.8% of the total demand) and the rest from surface water resources. Almost in all scenarios about 63 to 100% of the annual demands were supplied and in the most critical months at least 50 percent of the demands were supplied.
The highest percentage of annual deficit irrigation was 37% and observed in scenario including reduce groundwater extraction equal to 20% and deficit irrigation up to 50%. In scenarios with the same percentage of deficit irrigation, with a 20% reduction in groundwater extraction, the water supply was reduced by a maximum amount of 5%, and in scenarios with the same groundwater extraction volume and different percentages of deficit irrigation, the water supply was reduced by a maximum amount of 37%. Therefore, the GSA optimization model was able to solve the problems of conjunctive optimization of surface and groundwater resources by providing a model of optimal crops in water scarcity conditions and flexibility in different percentages of irrigation, while increasing the area of cultivation.

Study of affective phenomena on Sediment transport in local scouring around bridge piers

Volume 13, Issue 2, Autumn 2019, Pages 105-116

Elham Izadinia, Manuchehr Heidarpour

Abstract The structure of turbulent flow over the scour hole is important for understanding the sediment particle entrainment and transport. In the present study, stochastic nature of turbulent flow around a bridge pier under a clear water regime has been investigated experimentally. Inside the scour hole, near the bed, the flow does not have enough energy to transport the particles; hence, the sedimentation occurs in this region. The particles in the scour hole near the bed are lifted up, however, they cannot move along the flow and finally they return to the bed. By comparing depth average values of the occurrence probabilities at the pier upstream, it was found that the sweep events probability is more than other events, which followed by ejection, outward and inward interaction. Since the sweep events are dominant phenomena at the pier upstream, the maximum scour depth takes place at this region and the eroded sediments are transported heading downstream.
Scour is a natural event caused by the erosive action of flowing water on the bed and banks of streams, which also takes place on region near the bridge piers and abutments. The stochastic nature of turbulent flow around the bridge pier has been investigated only in handful studies; therefore, the precise effect of pier on sediment transport is yet unclear. Kline et al. (1967) have introduced the concept of bursting phenomenon as a mean to describe the momentum transfer between the turbulent and laminar region near the boundary. Lu and Willmarth (1973) introduced the quadrant analysis for studying the the bursting phenomenon structure. The quadrant analysis was employed to determine the occurrence frequency of each individual event within a bursting process, i.e. outward interactions, ejections, inward interactions, and sweeps. Jafari and Keshavarzi (2010) investigated turbulence flow and sediment entrainment over the ripples by using quadrant analysis. However, despite the importance of coherent structures of turbulence and in particular the bursting events around the bridge pier; their characteristics have not been investigated in detail. Since the quadrant analysis is a powerful technique to recognize the structure of the bursting phenomenon and consequently to find the susceptible regions for sediment entrainment and deposition, this technique is considered in the present study to investigate the coherent structure of turbulent flow in scouring process around the bridge pier.
The experiments were carried out in a smooth rectangular flume with 8 m length, 0.4 m width and 0.6 m height. The channel entrance was filled with sand in order to generate fully developed flows. The working section, in which piers were located, was 1.6 m long with a 0.15 m recess on the bed and was located 4 m downstream from the flume entrance. The recess was filled with 0.72 mm mean particle size uniform sediment and the standard geometric particles deviation was 1.12 mm. Uniform sand, having the same size as that used for the scouring test, was glued over the false floor. The velocity profiles were measured around the bridge pier. In each vertical profile at least 20 points were measured within the flow depth from the bed. The ADV readings were taken when the scour hole was at the equilibrium condition.
The variation of the fractional contributions, |Si, H|, as a function of the hole size H for each of the four quadrants at z/h=0.2 (near the scour hole edge) at the up and downstream of the pier are shown in Fig. 1. At z/h=0.2, quadrant (II) and (IV) events are dominant and quadrant (I) and (III) events appear to contribute weakly to the Reynolds shear stress production. Generally, by increasing the hole size, the contribution of each event to the Reynolds shear stress generation becomes small. As indicated in Fig. 1, at the pier upstream at z/h=0.2, ejection (|S2,0|?0.8) is the dominant event which is followed by sweep (|S4,0|?0.6). The sweep contribution tothe Reynolds shear stress production becomes negligible for H>10, whereas the ejection contribution is significant even at H>20. On the other hand, the contributions of outward and inward interactions to the Reynolds shear stress are rather weak (|S1,0|=|S3,0|?0.2). These contributions vanish when H>6 and H>10 for quadrant (III) and (I), respectively.
At the pier downstream, the contribution of each event to the Reynolds shear stress production is more significant than pier upsream. In this region, at z/h=0.2, the contributions of ejection and sweep become comparable (|S2,0|=|S4,0|?1.4) and both are greater than the outward (|S1,0|?0.9) and inward interaction (|S3,0|?1). For each of the four quadrants at z/h=0.2 in the pier downstream the contribution of each event to the Reynolds shear stress is still significant for hole sizes as large as H>20. Therefore, at the pier downstream, although quadrant (II) and (IV) are more significant, each of the four quadrants has important effects on the Reynolds shear stress.

Modification of Kostiakov infiltration equation based on influence of initial soil water content

Volume 13, Issue 1, Spring 2019, Pages 157-163

Jahanshir Mohammadzadeh-Habili, Manouchehr Heidarpour

Abstract Infiltration is one of the most important parts of hydrologic cycle by which surface run off, groundwater recharge and design of irrigation systems can be linked. Numerous equations, some entirely empirical and others physically based, have been proposed over the years to express infiltration as a function of time. Among these equations, due to the simplicity and capability of fitting on most measured infiltration test data, the Kostiakov infiltration equation is widely used for design of irrigation systems. Influence of initial soil water content is not considered in this important equation. This study aims to investigate the effect of initial soil water content on empirical parameters of Kostiakov infiltration equation and to modify the equation based on influence of initial soil water content.
In this research, two uniform sandy soils were prepared by passing a sandy soil through sieves. Following that, the two soil samples were dried at oven at 105 oC for 24 hr. Each dry soil sample was placed in a transparent acrylic cylinder with inner diameter of 7 cm and smoothly compacted by kicking a rubber hammer on cylinder body. After that, an initial water depth was placed on soil surface and falling head cumulative infiltration depth through the soil column was measured with the time. After diminishing of water level on soil surface, the humid soil column was drained by using a vacuum pomp. Then, the soil column water content was measured and the falling head infiltration test was repeated on the soil column. For two studied soil columns, falling head infiltration tests were conducted in three different values of initial soil water contents. To extend the experimental results to the field scale, a falling head infiltration test was also conducted on a clay textured field by using the double ring infiltrometers, with inner ring diameter of 25 cm, and outer ring diameter of 40 cm. Both the inner and outer rings were filled with the same initial water depth. Falling water level in inner ring was measured before water level would reach the soil surface. Simultaneously with last reading of water level, the two rings were pooled out and vertical distance from the soil surface to the wetting front was measured using an auger. Additionally, a steel cylinder was used and a soil sample with volume of 293 cm3 was taken from the vicinity of field test location and field initial soil water content was measured. For laboratory and field tests, wetness increment behind the wetting front was estimated by dividing the total infiltrated water through the soil by the depth of wetting front. The water content behind the wetting front of laboratory and field tests was also estimated by adding the wetness increment with initial water content. For laboratory and field tests, the Kostiakov infiltration equation is fitted on measured cumulative infiltration test data and empirical parameters of the equation are estimated for each test.
Comparison between measured cumulative infiltration tests data of each laboratory soil column in different values of initial water contents indicated that water infiltration through the soil is strongly influenced by initial soil water content. With increasing initial soil water content, cumulative infiltration depth through the soil is significantly reduced. Additionally, laboratory results indicated that water content behind the wetting front of infiltration is a constant value and is not influenced by initial soil water content. Laboratory results indicated that the power of Kostiakov equation (b) is a constant value and is not influenced by initial soil water content, while the coefficient of equation (a) is strongly influenced by initial water content. With increasing initial soil water content, the a coefficient of Kostiakov equation is reduced. After analysis of experimental results, a coefficient of Kostiakov infiltration equation is related to the initial soil water content and the water content behind the wetting front of infiltration. Laboratory results were extended to the field scale. Based on laboratory results, the b coefficient of Kostiakov equation for the studied field was taken as a constant value. The obtained empirical equation for the a coefficient of Kostiakov equation was used and the a coefficient for the studied field was related to the initial soil water content and the water content behind the wetting front.

A study of Eeffect of barley straw as organic filter on reduction of drainage water nitrate

Volume 10, Issue 1, Spring 2016, Pages 87-96

shahab ansari, manuchehr heidarpour, farhad mousavi

Abstract Nowadays farmers often use N-fertilizers to increase crop yield. On the other hand, in agricultural lands nitrogen fertilizers, usually lost quickly by leaching, cause contamination of water resources and soil that reported as the most important source of pollutant. Also, treating and reusing drainage water is necessary because of a shortage of water resources, especially in arid and semi-arid regions. Although biofilters are useful for removing nitrate from drainage water, but many researches show that they need an external carbon source to sustain denitrification. Many researchers have studied on different method, but most of them need equipment or material that becoming use in the laboratory experiment. For example, mixing these biofilters and soil in large-scale underground drainage systems is very difficult and costly. So this study describes laboratory experiments that investigated nitrate removal from drainage water with barley straw in different percentages layered or mixed with soil in columns. The columns’ nominal diameter and height were 9 and 30 cm, respectively. There were two groups of treatments in this study. In the first group, the columns were filled with 3 layers of soil and 2 layers of barley straw between them (layered treatments). In the second group, the columns were filled with a mixture of soil and barley straw (mixed treatments). In both groups, barley straw was used in three levels of 10, 20 and 30 percent of volume. In layered treatments, the thickness of the 2 layers of barley straw was equal and proportionate to the percentages of its usage. The experiment lasted for 77 days. The influent drainage water contaminated with nitrate of 80 mg/L concentration.
According to the results, the concentration of nitrate from all effluent of treatments decreased with the passing of time. The highest percentage of barley straw was more effective in removing nitrate than the treatments. The control treatment (without barley straw) reduced less than 25% of the nitrate concentration of the influent. So the lump of earth cannot often reduce nitrate denitrification significantly due to a shortage of carbon source while water passes through it. Ammonium concentration of the effluent in all the treatments has decreased with the passing of time. On the other hand, the results show that a small amount of ammonium could be consumed under the anaerobic condition owing to the growth of anaerobic bacteria cells. The pH and EC values didn’t have a particular procedure during the experiment, the effluent values almost followed the influent procedure, but the pH effluent values have been always less than the influents. These values fluctuated between 7.18 and 7.95, which are close to the pH of soil saturation extract. This may be due to unexpected variation of the influent pH and soil buffering characteristics that did not allow dramatic changes in pH. Also maximum nitrate removal by denitrification occurred in the pH range of 7.2-8.4, that was about the pH of the soil in this study. The results showed that as long as pH was between neutral to a little alkaline denitrification effect was excellent. On the other hand, high acidic and alkaline environment was not fit for denitrification, and pH value played an important role in nitrite accumulation. The main reason was that pH influenced the enzyme activity of bacteria.
In this study, biological nitrate removal was investigated applying 10, 20, and 30% volume of barley straw (as layered or mixed treatment) in soil columns, under water flow for 11 weeks. Layered and mixed treatments were compared because mixing barley and soil in large volumes needed in underground drainage systems is sometimes difficult or impossible, costly and requires advanced equipment. Results proved all the treatments to be profitable. Also, the results showed that the optimum treatment with maximum nitrate removal efficiency (80%) was the 20% layered treatment. Ammonium concentration of the effluent decreased in all treatments with the passing of time, but it was almost close to influent values. Furthermore, variation of pH levels of the treatments didn’t have a particular procedure during the experiment and almost followed the influent procedure. So the application of the barley straw in layering method is a practicable inexpensive solution to achieve higher nitrate removal efficiency compared to mixing method or other bioreactors without having to be worried about of side effects and dangers of pH in effluent drainage water that can be used in artificially recharge systems or reusing wastewater as irrigation water.

Determine the Best Coverage Pattern of Geotextile for Reduction Scour around Cylindrical Group Piers

Volume 9, Issue 4, Winter 2016, Pages 69-77

Ali Nouri Emamzadehei, Manochehr Heydarpoor, Mohammadreza Nouri Imamzadehei, Behzad Gorbani

Abstract Flood currents are considered as a threatening factor which creating local scour along bridge piers. In studying the reasons for the destruction of many bridges, scour resulting from flood currents has been identified as the major reason for the failure. Scour is a natural phenomenon which occurs as a result of erosion in bed and drift riversides by water current. This phenomenon is created locally as a result of mutual effect of water way geometry, bed and current specifications around the pier. As a matter of fact, when a current strikes bridge pier, holes are made around the pier and complex vortex systems are created whose performance causes a hole around piers called a scour hole. The development of this hole around the pier causes under the foundations to get empty leading to their destruction and finally the destruction of the bridge. In order to prevent and decrease scour at the bridge pier, two basic methods have been presented. One of them is the direct method in which the resistance of the bed against tension increases; and the other is the indirect method in which the effect of the destructive forces is reduced by changing the current pattern around the pier. Prediction of depth and the final status of scour hole are the most important cases of hydraulic design of bridges. Geotextiles, which are produced from polypropylene and polyester fibers, form a large group of geosynthetic products. These materials can be used to strengthen river beds adjacent to bridge piers and to control the scour around them concurrently playing the role of riprap and collar. Geotextile spread around bridge piers to prevent the scouring around it. In terms of economics, determine the extent and pattern of suitable geotextile cover is essential.
In this study, coverage area with geotextile around the single pier and a group of two and three piers in the case of clear-water flow over uniform sediment were investigated. The experiments were carried out in a 20m long, 0.60m wide, and 0.60m deep, Plexiglass-sided flume. The piers of Teflon were selected with 5cm diameter and fixed parallel the streamline. The space between the piers was 3 times bigger than pier diameter. The granulated silt of bed materials was chosen so that no ripples are formed in the test area bed. The formation of ripples causes separate small protrusions in the bed; it also causes an increase in current speed compared to the critical speed in the movement threshold of sediments causing some of the upstream sediments of the pier to be washed and carried thus filling the scour hole and causing the scour depth to decrease compared to its real maximum amount. Ripples and non-sticking sediments with mean sized from 0.05 to 0.7 mm develop; hence, the mean diameter of sediments should be over 0.7mm.
The results showed that in group piers the sheltering effect of the first pier decreases 50% of coverage pattern and the reinforcing effect of the last pier increase the coverage pattern about 40%. Sheltering effect in a group of two and three piers let to decreasing scour hole about 50% and 71%, respectively, than the single pier. At the rear pier of a group of three piers, the dimensions of the scour hole were 21% less than a group of two piers because the first and second piers protect the rear pier. With experiment on coverage patterns, it was found that the oval layer in single pier and the semi oval layer in group piers is the best pattern for scour reduction. In this state, after 19 hours, the first signs of scour in downstream are observed whose longitudinal and widthwise progression were about 3cm to the end of the test and its depth, too, reached 0.5cm. Base on the obtained results, with regard to the negligible amount of scour, the semi-oval pattern with more coverage in behind the pier is suggested as the best pattern in geotextile installation. By using geotextile with an appropriate cover, apart from a delay in scouring process, the scour location is transferred to downstream and the scour depth is decreased. In other words, the geotextile layer has a dual performance in decreasing scour. As far as economy and method of application are concerned, the larger layer; and as far as the scour is concerned, the smaller layer would be problematic.

Experimental study of triangular labyrinth weirs with guide vanes

Volume 9, Issue 3, Autumn 2015, Pages 57-65

seyedeh zahra hosseini teshnizi, manouchehr heidarpour, seyed saeid eslamian

Abstract Weirs are used in different ways to control water levels and flow measurement. One of the most effective and economical way to increase the effective length of weir is using labyrinth spillways. The direction of flow of the labyrinth spillways is not perpendicular to the edge of the weir and it is oblique. On the upstream and downstream of the weir, the flow direction of the symmetry axis of labyrinth weirs is parallel. This phenomenon is more common in the downstream overflow because of flow stacking and, thus efficiency of weir is reduced (Hay the Taylor, 1970). Since, study about the using of upstream guide vanes in the direct channel has not been yet published, in this paper, flow guide vanes were used in the upstream of the triangular labyrinth spillway with vertex angles of 45° or 90°. The main purpose is guiding flow on weir wall perpendicularly and study of discharge coefficient.
The experiments were conducted in a canal with a length of 7 m, width of 0.32 m and height of 0.36m. The two triangular labyrinth spillways with vertex angle of 45° and 90° were used. The models were made of galvanized sheet with 1 mm thickness and smooth overflow threshold edge. According to previous researchers (w/P?2.5, in this case P is weir height and w is canal width), the height of the weir was considered equal to 12 cm. A direct spillway with the same width was used to calculate the equivalent discharge. Guide vanes were made from galvanized steel plates. The height of guide vanes was 12 cm and their widths were 2, 3, 4 and 5 cm. The width of guide vanes was a coefficient of the length of one side spillway. Spillways were installed at a distance of 4.5 meters from the beginning of the canal. The reason of choosing this distance is that the flow completely developed from 3.5 to 4.5 meters from the beginning of the canal. Height and velocity of upstream water flow were taken at 5 discharges. The upstream depth of water, above the weir and longitudinal profile of the water surface was measured by a depth meter. Acoustic Doppler Velocimeter was used to measure the flow velocity. The tests were conducted in 3 groups: Group I at vertex angle of 45 or 90°, the width of guide vanes were 2, 3, 4 or 5 cm at a direct distance of 8 cm from the weir with 45° wall angle. Group II at vertex angle of 45 or 90°, wall angle guide vanes with weir of 35, 45, 65 or 90 degrees at direct distance of 8 cm from the weir. Group III at vertex angle of 90°, direct distance of 8, 22 or 33 cm from the center.
In this study, Group I on the weir at vertex angle of 90 degrees and direct distance of 8 cm from the upstream weir does not positive effect on overflow efficiency, because efficiency in all tests were less than simple triangular labyrinth spillway with vertex angle of 90 degrees. The comparison shows that the highest efficiency occurred on weir with vertex angle of 45 degrees with guide vane width of 2 cm and on weir with vertex angle of 90 degrees without guide vane. In group II at the weir with vertex angle of 90 degrees, existence of guide vanes at direct distance of 8 cm from the weir with all angles of 35, 45, 65 and 90 degrees is reduced efficiency of flow. It is determined by comparing the curve of models, the maximum of efficiency occurred with vertex angle of 45 degrees and wall angle of 35 degrees, and on weir with vertex angle of 90 degrees and wall angle of 35 degrees. In group III, efficiency in all tests were less than simple triangular labyrinth spillway with vertex angle of 90 degrees and adistance of 8, 22 and 33 cm. In triangular labyrinth spillway with small vertex angle, using guide vanes could affect on vertical velocity component and this component could be increased. So at the same time, the flow is passed more quickly from weir crest, discharge is increased then for the same height water, the discharge coefficient increased. It was found that the triangular labyrinth weir with less vertex angle had very disturbance flow with increasing of discharge. These vanes could be guided flow perpendicularly on wall weir and then efficiency was improved.

Determination of discharge coefficient for the combined model of semicircle weir and sluice gate in the circular channel

Volume 7, Issue 2, October 2013, Pages 149-155

Manouchehr Heidarpour, Sayed Hosein Razavian, Yasin Hoseini

Abstract Many devices and methods are available for the measurement and control of flow rate in open irrigation channels. Among, these devices, sharp crested weirs and sluice gates are commonly used. In order to minimize the disadvantages of weir and gate, they can be combined together in one device yielding a simultaneous flow over the weir and below the gate. In this study the hydraulic characteristics of combined device of weir-gate such as coefficient of discharge and effective parameter on simultaneous discharge were investigated. The relationship between the experimental and theoretical results of the geometric and hydraulic parameters in the function of the flow statistically was analyzed and a coefficient discharge for combinational flow was presented. The error from the application of equation for 95% of data was ±2.5 percent.

Determination of complete mixing length in a rectangular flume

Volume 5, Issue 2, October 2011, Pages 11-18

Alieh Saadatpour, Manouchehr Heidarpour, Sayyed-Hassan Tabatabaei

Abstract Transverse mixing coefficient is one of the hydraulic parameters of flow by which the amount of self-refinement and dilution of river water can be estimated. In this research, the effect of variations of width to depth ratio on the transverse mixing coefficient was studied. Experiments were carried out in a straight rectangular flume of 7 m length, 0.32m width and 0.35m height. The maximum flow rate was 16.4 lit/s. Water was circulated in the channel, the flow was uniform and the depth of water was controlled with a gate way. A tracer was continuously injected with a constant head into the center of the flume. Dye concentration was measured at 4 different downstream locations from the injection point; Twenty seven points were measured and dimensionless transverse mixing coefficient was determined. The results showed that increasing the width to depth ratio from 2.8 to 5.69, the transition by secondary flow increased. Accordingly, in constant velocity of 0.33 m2/s, transverse mixing coefficient decreased from 5.621 to 11.4 by increasing the depth from 0.04945 to 0.0121 cm.